Top One Innovator & Manufacturer of Circular Conveyor System in China!

Technical Guide

How To Set Elliptical Circular Conveyor Track Dimensions: Model Code, Envelope and the Two Widths That Change Everything

How to set Elliptical Track Dimensions?

Author: ChangMing, Director of engineering department| 19th, Spet 2026 | Category: Technical Guide

Elliptical track dimensions are the geometric parameters that define a closed-loop guide rail made of two parallel straight sections joined by two 180° curved segments. The key dimensions are the arc radius (R), which sets the curve geometry and carriage compatibility; the center distance (L), or straight-section length between arc centers; the overall length (L + 2R + rail width) and overall width (2R + rail width), which define the system footprint; and the rail cross-section, meaning height and width. Mounting-hole pitch and carriage spacing complete the specification. Together, these values determine layout fit, cycle path length, and the number of workstations a circular conveyor can support.

An elliptical track set is the most common closed-loop geometry on a circular conveyor: two 180° arcs joined by two straight sections. This page gives the model code, the assembly dimensions for every published combination, the two places where the dimensions stop scaling smoothly, and the envelope arithmetic that decides whether a chosen arc will fit the floor.

Model code in Elliptical Track Set Dimensions

V25 – S255 – R180 – L1980 – 4P

  • V25 — guide rail model (V-type or T-type) and guideway width: 23, 25, 28, 30, 44, 50 mm
  • S255 — arc diameter: 200, 255, 300, 351, 400, 468, 500, 600, 612 mm
  • R180 — arc angle: 90° or 180°
  • L1980 — straight rail length
  • 4P — number of sliding carriages

One note on the L field before any arithmetic: state on the order whether the figure is the straight length per side or the total of both sides. Everything below is worked in total straight length, because that is what the path arithmetic needs.

Assembly dimensions

Model A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) P (mm)
V25-S200R180 100 80 85 45 60 per configuration per configuration
V25-S255R180 100 80 85 45 60 per configuration per configuration
V25-S300R180 100 80 85 45 60 per configuration per configuration
V25-S351R180 100 80 85 45 60 per configuration per configuration
V25-S400R180 100 80 85 45 60 per configuration per configuration
V30-S255R180 95 108 80 76 50 5 (0.02/0) 30
V30-S351R180 95 108 80 76 50 5 (0.02/0) 30
V30-S468R180 95 108 80 76 50 5 (0.02/0) 30
V30-S612R180 95 108 80 76 50 5 (0.02/0) 30
V44-S468R180 110 130 90 90 50 5 (0.02/0) 30
V44-S612R180 110 130 90 90 50 5 (0.02/0) 30
V50-S468R180 130 150 120 120 50 5 (0.02/0) 40
V50-S612R180 130 150 120 120 50 5 (0.02/0) 40

F is the parallelism tolerance on the mounting interface; on the V25 series F and P are confirmed per configuration at quotation.

Guide rail group section

Model G h (mm) H (mm) M (mm) S (mm)
V25-S200R180 M5 15 35.5 200 90
V25-S255R180 M5 15 35.5 255 90
V25-S300R180 M5 15 35.5 300 90
V25-S351R180 M5 15 35.5 351 90
V25-S400R180 M5 15 35.5 400 60
V30-S255R180 M6 18 35.5 255 40
V30-S351R180 M6 18 40 351 40
V30-S468R180 M6 18 40 468 40
V30-S612R180 M6 18 40 612 40
V44-S468R180 M6 21 45 468 90
V44-S612R180 M6 21 45 468 90
V50-S468R180 M8 21 46 468 60
V50-S612R180 M8 21 46 612 60

M is the arc diameter and reproduces the S-field of the model code. H is the overall height of the guide rail group, h the mounting-face height, G the fixing thread, S the fixing hole spacing.

H and h answer different questions. H is what the process equipment above the carrier has to clear. h is what the frame below has to accommodate. Checking one and assuming the other is a common way to lose a week late in a layout.

Thirteen combinations, six mounting groups

The useful question is not how many combinations exist but how many distinct mounting interfaces they present, because that is what decides whether a base plate can be reused.

Group Combinations A / B G h / H S
1 V25 at 200, 255, 300, 351 100 / 80 M5 15 / 35.5 90
2 V25 at 400 100 / 80 M5 15 / 35.5 60
3 V30 at 255 95 / 108 M6 18 / 35.5 40
4 V30 at 351, 468, 612 95 / 108 M6 18 / 40 40
5 V44 at 468, 612 110 / 130 M6 21 / 45 90
6 V50 at 468, 612 130 / 150 M8 21 / 46 60

Two of the four series split, and they split for different reasons.

V25 splits on fixing hole spacing at S400. Groups 1 and 2 share every other dimension, but the drilling changes from 90 mm to 60 mm. A base plate made for a V25-S351 will not bolt to a V25-S400.

V30 splits on height at S351. Groups 3 and 4 share the drilling, so the base plate carries across — but the carrier sits 4.5 mm higher on the larger arcs. Where vertical clearance is tight, that is the difference between fitting and not.

The practical rule is the same in both cases: check the specific combination, not the series. “It is a V30 set” is not enough information to reuse a plate or to sign off a clearance.

Six mounting groups across the elliptical track set range, showing where hole spacing and height step

Thirteen published combinations regrouped into six distinct mounting interfaces, with the two split points marked.

Arc diameter does not change the slide group

Every V30 combination shares A 95 / B 108 whether the arc is 255 or 612, and the same holds for V25, V44 and V50. Arc diameter changes the loop envelope; it does not change the slide group envelope.

That has a useful consequence at the point where it is usually needed. Cycle time problems are most often solved by opening out the arc, and that change costs floor space but requires no change at all to the mounting interface — subject only to the V30 height step above.

V30 is narrower than V25 in the A dimension. A drops from 100 to 95 going from V25 to V30, while B rises from 80 to 108. The two series have different slide group proportions, not a scaled version of the same one — a V25 mounting pattern is not a subset of a V30 one, and swapping series mid-design means re-cutting the base plate.

The fixing spacing follows the rail model. S on the track set is the drilling pattern of the guideway itself, which is why it changes within V25 rather than being a property of the set. Rail-side hole positions and the end-distance rule are on Circular Guide Rail Selection.

The envelope arithmetic in Elliptical Track Set Dimensions

An elliptical loop is two 180° arcs and two straights, so the path the carriers travel is:

path length = total straight length + π × arc diameter

and the loop must close on a whole number of carrier pitches, so that path equals the carrier count times the pitch. Turning that around gives the two numbers a layout actually needs.

The arc consumes π × D of path before any straight exists.

That sets a floor on the loop:

Arc diameter (mm) Path consumed by the two arcs (mm)
200 628
255 801
300 943
351 1,103
400 1,257
468 1,470
500 1,571
600 1,885
612 1,923

A loop of eight carriers at 240 mm pitch has 1,920 mm of path in total — which will not close on a 612 mm arc at all, because the arcs alone need 1,923 mm. Carrier count times pitch has to exceed π × D before the geometry is possible, and on the larger arcs that is a real constraint rather than a formality.

Opening the arc makes the loop shorter and wider, not simply bigger.

This is the result most people get backwards. At a fixed carrier count and pitch the path length is fixed, so a larger arc takes path away from the straights:

total straight length = (carriers × pitch) − π × D

Worked on a loop of eight carriers at 320 mm pitch — 2,560 mm of path:

Items 468 mm arc 612 mm arc
Path in the arcs 1,470 mm 1,923 mm
Straight per side 545 mm 319 mm
Overall length (straight + arc) 1,013 mm 931 mm
Overall width 468 mm 612 mm
Footprint area 0.47 m² 0.57 m²

The loop gets 82 mm shorter and 144 mm wider, and the floor area rises about 20%. So the answer to “will the bigger arc fit?” depends entirely on which way the space is tight. In a long narrow bay it may fit more easily than the smaller arc; across a constrained width it will not fit at all.

Add the slide group envelope to those figures before comparing against the available space — the carrier overhangs the rail by the A and B dimensions, and the process equipment above it needs its own clearance.

Elliptical track set dimensions compared at equal path length on 468 mm and 612 mm arcs.

Two loops of the same path length on different arc diameters: the larger arc gives a shorter, wider loop.

Selecting the arc in Elliptical Track Set Dimensions

Arc diameter is rarely chosen on envelope alone. It is usually forced by cycle time, because attainable speed falls on a smaller arc at a given slide load, and because a smaller arc imposes a larger lateral acceleration on whatever the carrier is holding. The selection order that eliminates options fastest is fixture envelope against arc diameter first, then load against speed on the capacity curve — worked examples on Conveyor Cycle Time Calculation.

Straight-section length follows from the number of carriages and the pitch; the full loop arithmetic including the end sections is on Circular Conveyor Loop Parameters.

Where Elliptical Track Set Dimension usually goes wrong

Reusing a base plate across a series. V25 changes drilling at S400 and V30 changes height at S351. Neither announces itself in the model code.

Assuming a larger arc needs more length. At constant path it needs less, and more width.

Choosing an arc without checking that the path can close on it. π × D is consumed before any straight exists.

Checking H and forgetting h, or the reverse. One is clearance above, the other is the frame below.

Swapping series to gain capacity mid-design. V25 and V30 are not scaled versions of each other; the plate is re-cut.

How to Make Circular Conveyor Maintenance and Troubleshooting?

Sources and references

Primary sources are first-party. The model code fields, the assembly dimension table, the guide rail group section table and the arc diameter range are taken from the Circular Conveyor System catalogue (edition 2027.1) and from engineering confirmations recorded during its revision.

Envelope arithmetic. The path relation, the π × D floor and the worked footprint comparison are elementary geometry applied to the published arc diameters, shown in the text so a reader can check them. Footprint figures are the loop envelope only and exclude the slide group and any process clearance, which is stated where they appear.

The mounting group table is a regrouping of the two published tables by the dimensions that decide interchangeability. It introduces no figure that is not in them.

How to Set Rectangular Track Dimensions?

 

Prev:

Next: