Cylinder Stop Positioning Conveyor: One Actuator per Station
Author: ChangMing, director of engineering department | Sept 2026| Category: Technical Guide
The second positioning mechanism family drives each locator with its own cylinder acting directly on the carrier, rather than linking several locators to one actuator. It buys independence at every station, and it costs a cylinder at every station.
Model code in C Motion Cylinder Stop Positioning Conveyor
LDS – 01
- LDS — linear actuated locator, direct-acting
- 01 — locator quantity
Note that unlike the linkage-rod code, there is no station-pitch field. Each locator is independent of the others, so pitch is not built into the hardware. This is the practical difference between the two families, and it is visible in the model code before it is visible anywhere else.
Two mounting configurations in C Motion Cylinder Stop Positioning Conveyor
Panel cylinder positioning. Suited to panel frame construction — where the line is built on plate rather than extrusion.
Cylinder direct-acting positioning. Suited to profile frame construction — aluminium extrusion.
The two differ in how the cylinder is mounted and located, not in what they do to the carrier. Frame type is normally already settled by the line design, so this choice usually follows rather than leads.
There is one consequence worth carrying forward from it. The locator has to react the process force through its own mounting into the frame, so the stiffness of that path is part of the positioning specification and not just a fixing detail. On a profile frame, check the clamping of the locator mount specifically. A T-slot connection that creeps under repeated load moves the station datum, and it does so slowly enough that it reads as drift rather than as a loose bolt.
Cylinder selection in C Motion Cylinder Stop Positioning Conveyor
Cylinders are AirTAC, SMC, or a brand appointed by the customer. Plants with an established pneumatic standard can carry it across, so spares holdings and maintenance procedures already in place continue to apply.
Independent per station: what that buys
Arbitrary timing. Each station clamps and releases when its own process needs it. A station that must hold a workpiece through a five-second cure while the neighbouring station indexes twice is straightforward here and impossible on a shared rod.
Pitch is free. Because no hardware spans between stations, changing the station pitch is a layout change, not a hardware change. Re-pitching a line with linkage-rod positioning means a new connecting rod; re-pitching one with individual cylinders means moving the cylinders.
No accumulated pitch tolerance. Each locator is positioned against the frame directly rather than through a rod carrying two or three spacings. That does not make the position error zero — it makes it per-station and random rather than cumulative, and what is left is the frame’s own accuracy, which is an absolute-accuracy question rather than a repeatability one. Frame flatness and what it governs are on Circular Guide Rail Joint Accuracy.
Failure is local. One cylinder failing takes out one station. Whether the line can then run degraded with that station skipped is a control-system decision rather than a property of the hardware — the carrier has to be allowed to pass unworked and the sequence has to tolerate it. If degraded running is the reason for choosing this family, specify it as a control requirement, not as an expected side effect.
The cost is part count, and it is more than the cylinders
Every station is a cylinder, a valve, a pair of fittings, tubing and a control signal. On a twelve-station line, against four shared triple rods:
| Four triple rods | Twelve individual cylinders | |
| Cylinders | 4 | 12 |
| Valves and solenoids | 4 | 12 |
| Control outputs | 4 | 12 |
| Tube runs | 4 | 12 |
| Fittings, and therefore leak paths | 8 | 24 |
| Instantaneous air demand if all fire together | 4 cylinders | 12 cylinders |
Two of those rows matter more than the headline count.
Control outputs can cross a hardware boundary. Four outputs and twelve outputs are not the same purchase if twelve means another PLC card, and that cost does not appear in a conveyor quotation.
Instantaneous air demand triples. Twelve cylinders drawing at the same instant is a much larger demand than four, and if the manifold and receiver are not sized for it the pressure dips during the stroke. A lower pressure is a lower clamping force at every station at the same moment, which appears as positioning scatter and not as a pressure alarm — it is one of the more common reasons a line meets its figure at commissioning, when stations are proved one at a time, and misses it in production.
The remedy is the same property that created the problem. Individual cylinders can be staggered; linked rods cannot. Firing the stations in two or three groups a few tens of milliseconds apart flattens the demand without costing cycle time, and it is free in the control program. Where independence has been paid for, it is worth actually using it.

A twelve-station line compared as four shared rods against twelve individual cylinders.
Accuracy of Cylinder Stop Positioning Conveyor
With a positioning mechanism fitted, published repeat positioning accuracy is ±0.03 mm on chain drive and ±0.05 mm on timing belt drive. Without one, ±0.5 mm.
That figure is the repeatability of the stop the carrier is pulled onto. It is the same figure for both mechanism families — the choice between them is about timing, pitch flexibility and part count, not about achievable accuracy.
Two qualifications belong with it. The figure is along the direction of travel, and which other axes are held depends on the geometry of the datum the locator engages — a stop pressing on a flat face holds one axis and leaves the radial position to the guideway. And it describes one carrier at one station. Both are on Circular Conveyor Positioning Accuracy.
The clamping force at the locator and the maximum process force it can react before the carrier is pushed off its datum are confirmed per application at quotation. The second matters most on pressing and screwdriving stations, where the process applies a force to the workpiece while it is held, and it is worth asking for explicitly rather than assuming the positioning figure implies it.
Choosing between the two families
| Linkage rod (LKB) | Individual cylinder (LDS) | |
| Actuators | One per group | One per station |
| Station timing | Simultaneous within a group | Independent |
| Station pitch | Fixed in hardware | Free |
| Pitch tolerance | Along the rod, and compensable | Per station |
| Control I/O | One signal per group | One signal per station |
| Instantaneous air demand | Lower | Higher, but staggerable |
| Failure effect | Group | Single station |
| Accuracy | Same | Same |
Specify individual cylinders when stations need independent timing, when the pitch may change over the line’s life, when stations are widely spaced, or when a single station failure must not stop the line.
Specify linkage rods when adjacent stations clamp together anyway, the pitch is settled, and reducing part count and control I/O matters — Pneumatic Rod Positioning Mechanism.
Mixing both on one line is possible and is often the right answer: shared rods on runs of stations that work together, individual cylinders where a station needs to act on its own. The grouping procedure — by clamp window rather than by physical position — is on the rod page.

A mixed architecture: shared rods on the nine stations that clamp together, individual cylinders on the three that do not.
Where cylinder stop specification usually goes wrong
Costing it as twelve cylinders. It is twelve of everything, including control outputs and leak paths.
Sizing the air supply for one cylinder. Twelve firing together is the load case, and the symptom of getting it wrong is positioning scatter, not a pressure alarm.
Paying for independence and then firing everything simultaneously. Staggering is free and it flattens the demand.
Expecting degraded running without specifying it. It is a control requirement.
Bolting a locator to a profile frame and not checking the clamping. A T-slot joint that creeps moves the station datum.
Assuming the positioning figure implies a process force limit. It does not; ask for the reaction limit separately.
Sources and references
Primary sources are first-party. The model code, the two mounting configurations, the cylinder brand options, the repeat positioning accuracy figures and the statement that the accuracy is the same for both families are taken from the Circular Conveyor System catalogue (edition 2027.1) and from engineering confirmations recorded during its revision.
The part-count table is arithmetic on a twelve-station line at the published rod configurations. The instantaneous air demand row follows from the count and is stated as a count of cylinders rather than as a flow figure, which would depend on bore, stroke and supply.
The manifold pressure consequence is the mechanism described on Circular Conveyor Positioning Accuracy, applied here to the higher simultaneous count of this architecture.
Circular Conveyor System Manufacturer