Why a Payload Figure in Kilograms Is Not an Answer in Conveyor Slide Load Calculation?
Author: ChangMing| Published: 14th, Sept 2026 | Category: Technical Guide
Ask how much a circular conveyor slide can carry and the usual answer is a single number in kilograms. That number is only meaningful if the load sits exactly over the slide, never accelerates, and the line runs flat. On a real production line none of those hold. The fixture overhangs, the workpiece sits above the mounting face, the slide stops twelve times a minute, and half the loop is an arc.
A slide carriage on a circular guideway is a rolling element under combined loading. It sees a vertical force, a lateral force, and moments about three axes, all at the same time, and every one of them consumes part of the same roller-to-rail contact capacity. The correct question is not “how many kilograms” but “how much of the slide’s total capacity does this application consume.”
This page sets out the five limits published for each slide size, the load factor that combines them, and a worked example on a V30 slide showing how a deceleration that looks harmless consumes a third of the available margin.
The five published limits in Conveyor Slide Load Calculation
Each slide model carries five independent maximum values — two forces and three moments. These are the denominators in every calculation that follows.
|
Slide model |
Fy max (N) | Fz max (N) | Mx max (N·m) | My max (N·m) |
Mz max (N·m) |
| V25 | 80 | 150 | 7 | 16 | 16 |
| V30 | 120 | 250 | 15 | 25 | 25 |
| V44 | 150 | 300 | 16 | 28 | 28 |
| V50 | 250 | 500 | 30 | 50 | 50 |
| T23 | 100 | 200 | 10 | 19 | 19 |
| T28 | 200 | 400 | 23 | 35 | 35 |
Two things are worth reading out of this table before any arithmetic.
Lateral capacity is roughly half of vertical capacity, in every size. 80 against 150, 120 against 250, 150 against 300, 250 against 500, 100 against 200, 200 against 400. The ratio holds across the whole range because it follows from the roller geometry, not from the size of the part. This single ratio governs the mounting-orientation decision discussed further down.
The moment limits are not proportional to the force limits. Going from V30 to V44 buys 25% more Fy and 20% more Fz, but only 7% more Mx. If an application is moment-limited rather than force-limited — which overhung fixtures usually are — stepping up one frame size may buy far less than expected. Check which term dominates before specifying a larger slide.
Axis convention in Conveyor Slide Load Calculation
The published limits are stated against the slide body, not against the line layout. Use this convention throughout:
- X — the direction of travel along the guideway
- Y — horizontal, perpendicular to travel
- Z — perpendicular to the mounting face of the slide
So Fz is the force pressing the fixture onto the slide face, Fy is the sideways force, Mx is roll about the travel axis, My is pitch about the lateral axis, and Mz is yaw about the face normal.
The load factor in Conveyor Slide Load Calculation
The five terms are combined into a single dimensionless load factor:
LF = Fy/Fy_max + Fz/Fz_max + Mx/Mx_max + My/My_max + Mz/Mz_max
LF must be less than 1.0
Note that this is a sum, not a maximum. This is the part most often got wrong. It is not enough for each individual term to sit inside its own limit — an application at 40% of Fz, 40% of My and 40% of Mx is at LF = 1.2 and is overloaded, even though no single value is anywhere near its published maximum.
The reason is physical. Every one of these five loadings resolves, at the contact between roller and rail, into pressure on the same finite contact area. A moment about one axis and a force along another both end up loading the same rollers. They add.

Worked example: 8 kg fixture on a V30 slide
Take a horizontally mounted line, V30 slide, and a fixture whose combined mass with workpiece is 8 kg. The centre of gravity sits 60 mm from the slide centre along the direction of travel, 40 mm off to one side, and 100 mm above the mounting face. The line indexes at 0.5 m/s and stops in 0.1 s.
Step 1 — static terms.
Weight force: 8 × 9.81 = 78.5 N, acting downward, so entirely on Fz.
- Fz term: 78.5 / 250 = 314
- Mx (roll) from the 40 mm lateral offset: 78.5 × 0.040 = 3.14 N·m → 3.14 / 15 = 209
- My (pitch) from the 60 mm along-travel offset: 78.5 × 0.060 = 4.71 N·m → 4.71 / 25 = 188
Static LF = 0.314 + 0.209 + 0.188 = 0.711
Comfortable. If the line never moved, this would be the end of it.
Step 2 — deceleration terms.
Stopping from 0.5 m/s in 0.1 s gives a = 5 m/s². The inertia force is 8 × 5 = 40 N acting along the direction of travel, applied at the centre of gravity — which is 100 mm above the mounting face.
- That 40 N at a 100 mm height adds a pitch moment: 40 × 0.100 = 4.0 N·m, on top of the static 4.71 N·m. My total = 8.71 N·m → 8.71 / 25 = 348
- The same 40 N, offset 40 mm laterally, adds a yaw moment: 40 × 0.040 = 1.6 N·m → 1.6 / 25 = 064
Total LF = 0.314 + 0.209 + 0.348 + 0.064 = 0.935
The fixture is unchanged. The mass is unchanged. Adding nothing but a normal indexing stop took the slide from 71% of capacity to 93.5%. The margin that looked generous is gone, and almost all of it went into the pitch term — because the centre of gravity is 100 mm up in the air, and deceleration acts on that lever arm.
The design lever is fixture height, not fixture mass. Bringing the centre of gravity down from 100 mm to 50 mm halves the dynamic pitch contribution and takes LF back to 0.855. Reducing the mass by the same proportion helps far less, because mass appears in the static terms too and the static terms were never the problem.
Mounting orientation changes the answer
Return to the lateral-to-vertical ratio noted earlier. On a horizontally mounted line, gravity loads Fz, whose limit is the larger of the two. Mount the same line vertically and gravity now loads Fy, whose limit is roughly half.
Same 8 kg fixture, same V30 slide, vertical mounting:
- Fy term: 78.5 / 120 = 654, against 0.314 in the horizontal case
Before a single moment term is added, the vertical line has consumed nearly two-thirds of its capacity on static weight alone. This is why a fixture that runs comfortably on a horizontal loop may need the next frame size up, or a reduced payload, when the same line is mounted vertically — and why vertical mounting should be settled before slide selection rather than after.
Where the load factor goes next in Conveyor Slide Load Calculation
LF is not only a pass/fail check. It is also the input to the service life calculation, where it enters as a squared or cubed term — so the difference between LF = 0.93 and LF = 0.70 is not a 25% difference in life but closer to a factor of two and a half.
That calculation is set out in Conveyor Slide Service Life Calculation.
If the load factor comes out above 1.0, the options in order of effectiveness are: lower the fixture centre of gravity, reduce the offsets, soften the deceleration ramp, then step up a frame size. Frame size is last because, as the limits table shows, moment capacity scales more slowly than force capacity.