What causes Circular Conveyor Positioning Accuracy?
Author: ChangMing |17th, Sept 2026| Category: Technical Guide
There is no single positioning accuracy figure for a circular conveyor. There are three, and which one applies depends on two things: whether the line has a secondary positioning mechanism, and what drives it.
Quoting the best of the three against a line that does not have the hardware to achieve it is the most common specification error on this product, and it is usually discovered at commissioning, when the process equipment above the carrier will not repeat.
|
Configuration |
Repeat positioning accuracy |
|
Chain drive, with positioning mechanism
|
±0.03 mm |
|
Timing belt drive, with positioning mechanism
|
±0.05 mm |
|
No positioning mechanism (either drive) |
±0.5 mm |
Always state the drive type alongside the figure. A specification that reads “±0.03 mm” without saying “chain drive” is an over-claim on a belt-driven line.
The order-of-magnitude step is the positioning mechanism, not the drive
Read the table again and the important gap is not the 0.02 mm between chain and belt. It is the factor of ten between a line with a positioning mechanism and one without.
That factor of ten exists because the two configurations are measuring completely different things.
Without a positioning mechanism, the carrier stops wherever the drive train leaves it. What you are measuring is the accumulated repeatability of the whole transmission — encoder resolution, gearbox backlash, chain pitch tolerance or belt tooth pitch, plus whatever the carrier’s own inertia contributes as it settles. Every one of those adds. ±0.5 mm is a realistic figure for that stack, and no amount of servo tuning collapses it, because most of the error is mechanical and downstream of the encoder.
With a positioning mechanism, the drive is no longer setting the position. The drive brings the carrier close — to roughly that same ±0.5 mm — and then a pneumatic rod or a cylinder stop engages a hard datum on the carrier and pulls it the rest of the way. The figure you are then measuring is the repeatability of that mechanical stop, which is an order of magnitude better because it is one hard contact rather than a chain of compliances.

Both scatter bands are drawn to the same scale. ±0.5 mm when the drive sets the position, ±0.03 mm when a mechanism does.
The design consequence is direct: if the process needs better than half a millimetre, the positioning mechanism is not an option, it is the mechanism that delivers the specification. Upgrading the servo, the gearbox or the drive belt on a line without one will not get there.
The two mechanism types and their configuration codes are covered on Pneumatic Rod Positioning Mechanism and Cylinder Stop Positioning Conveyor.
What a Circular Conveyor Positioning Accuracy figure actually claims
Before the figure of Circular Conveyor Positioning Accuracy can be written into a specification, four qualifiers have to be attached to it. None of them is printed in the catalogue, and all four change what the number means.
It describes one axis, or two, depending on which mechanism is fitted. The figure is always a statement about position along the direction of travel. Whether it also governs radial position — in or out relative to the track centre — depends on the geometry of the datum the mechanism engages, and the two mechanism types differ. Height is never set by either. A specification that quotes “±0.03 mm positioning accuracy” without naming an axis will be read by a customer’s inspection department as a three-axis claim, which it never is. The next section sets out which axes each type actually holds.
It describes one direction of approach. Repeatability measured while always arriving from the same side is a different quantity from repeatability measured while arriving from alternating sides, and the difference is not small. See the backlash arithmetic below.
It describes one carrier. A loop typically carries several. Each has its own datum feature, machined to its own tolerance, so the spread seen by a fixed piece of process equipment as different carriers visit the same station is wider than the spread of any one carrier returning to it.
It is a half-spread, not a statistical repeatability value. ±0.03 mm means the readings fall inside a 0.06 mm band. A customer testing to a machine-tool standard such as ISO 230-2 will not report the band; they will report a value computed from the standard deviation of the readings multiplied by a coverage factor. The two numbers come from the same data and do not match. Agreeing which convention the acceptance test uses, before the line ships, prevents an argument in which both parties are measuring correctly.
Which axes each positioning mechanism actually sets
The two mechanism types are usually presented as a choice of actuator. They are not. They constrain different numbers of degrees of freedom, and that difference decides which processes each one can carry.
The pneumatic rod mechanism engages a rod into a bush, and locates in two axes.
Along-track and radial position at that station are both set by the mechanism, so the ±0.03 mm or ±0.05 mm figure applies to both.
The cylinder stop presses against a flat face, and locates in one.
Along-track position is set by the mechanism. Radial position is whatever the rail, the roller preload and the rail mounting leave it, and repeats to a guideway figure rather than to a mechanism figure.
| Degree of freedom | Pneumatic rod (rod into bush) | Cylinder stop (flat face) |
| Along direction of travel | Set by mechanism | Set by mechanism |
| Radial (in/out of track centre) | Set by mechanism | Set by guideway |
| Vertical | Set by guideway | Set by guideway |
| Yaw about vertical axis | Not constrained by a single rod | Not constrained by the stop |
| Pitch about transverse axis | Resisted only by the guideway | Resisted only by the guideway |
Three things follow from that table, and all three are selection decisions rather than commissioning adjustments.
The process decides the mechanism, not the budget.
Anything that inserts, presses, dispenses or drives into the workpiece from above needs the position held in two axes, and that is the rod mechanism. A process that only has to be stopped at the right place along the loop — a read station, a transfer where the receiving device does its own locating, an operation whose tooling is compliant across the track — is fully served by the cylinder stop. Fitting the cheaper mechanism and then discovering the radial axis was never controlled is a rebuild, not a setting change.
A two-axis engagement is radially over-constrained by design.
The rail is already holding the carrier radially when the rod arrives. The rod adds a second radial constraint at the same instant, so the two are fighting, and the one that gives way is whichever is less stiff — the rod deflects, or the rollers unload on one side. This is normal and is what the published figure already accounts for, but it has a practical consequence: on a rod-located station, roller preload affects the achieved figure in both axes, not only through play. The eccentric roller setting is part of the positioning specification at those stations.
Neither type constrains yaw on its own.
A single rod fixes two translations at one point and leaves the carrier free to rotate about it; a single stop pad fixes one translation and nothing else.
Pitch is left to the guideway in both cases. Those unconstrained rotations are what the Abbe amplification described further down acts on — a tool point standing well above the carrier datum sees the carrier’s pitch multiplied by its height, and no positioning mechanism is removing it. General practice in pallet-transfer automation is consistent on this point: the stop and the locator are treated as two separate devices, one to arrest the carrier and one to position it, and where rotation has to be held as well, a second locating feature is added rather than the stop being made to do more. The same applies here. Where a tall fixture is unavoidable, the rotation comes out through a second contact, not through tightening the mechanism.
Rod geometry is what sets the radial figure
Two constructions are in common use, and they behave differently enough that the radial number follows from which one is fitted.
A conical lead-in with a cylindrical locating land is the usual arrangement.
The cone’s job is entry: it catches the bore while the carrier is still somewhere inside the drive’s own ±0.5 mm and cams it across until the land can enter. The land then does the locating, and because a land has to have diametral clearance to enter at all, that clearance is a direct term in the radial figure. Radial repeatability on this construction is therefore bounded by the fit, not by the actuator, and it degrades as the land and the bush wear.
A full taper into a matching tapered seat closes the clearance instead of living with it.
Contact is on the cone flanks rather than on a land, so the rod centres itself and the radial residual is small. The cost is paid elsewhere: the mechanism has to be free to travel until the cones seat, seating depth changes as the flanks wear, and a taper is far less tolerant of a chip or a film of oil in the joint than a land is, because contamination on a cone flank displaces the carrier radially rather than simply resisting entry.
The published ±0.03 mm and ±0.05 mm figures do not settle which is fitted, and reading them closely says why. They differ by drive type, and a self-centring taper’s radial repeatability has nothing to do with whether the loop is chained or belted. A drive-type dependence is an along-track signature. So the published figure should be read as an along-track number in both cases, with the radial figure following the rod geometry and the fit, and confirmed per configuration rather than inherited from the table.
Two practical consequences. If the process needs a stated radial number, ask for it in writing at quotation together with the rod and bush fit, rather than assuming the along-track figure covers it. And if radial position is critical over a long service life, the land clearance is the item to put on the inspection schedule, because it is the one term in the whole positioning budget that grows monotonically with cycles.
Where the ±0.5 mm comes from: the no-mechanism error budget
The ±0.5 mm figure is not a rounding of an unknown. It is the sum of contributions that can be estimated individually, and estimating them is worth the ten minutes because it shows which ones respond to money and which do not.
The dominant term is a friction deadband, not a resolution limit.
When the servo comes to rest, the carrier stops where the elastic force stored in the drive element balances the breakaway friction of the rollers on the rail. Anywhere inside that band is a stable resting position, so the carrier can settle anywhere in it:
deadband = F_s / k
where F_s is the breakaway friction force at the carrier and k is the stiffness of the drive path referred to the carrier, in N/mm. Both terms move the wrong way as the line gets bigger. A heavier fixture raises F_s. A longer run of chain or belt between the drive and the carrier lowers k. A line with 30 N of breakaway friction and a drive path stiffness of 60 N/mm at the carrier sits at 0.5 mm of deadband on that term alone, which is the published figure. (Illustrative values — the real pair is per line and follows from the carrier mass, the roller preload and the loop layout.)
Encoder resolution is never the limit.
Take a 17-bit encoder, a 20:1 reduction and a drive sprocket of 100 mm pitch diameter. The carrier moves π × 100 / 20 = 15.7 mm per motor revolution, so one encoder count is 15.7 / 131,072 ≈ 0.12 µm. That is four thousand times finer than the figure being quoted. Specifying a higher-resolution encoder to improve positioning on a line without a mechanism buys nothing.
Gearbox backlash is a reversal term, and the reduction ratio does not divide it.
This catches people out. Backlash on a planetary reducer is quoted at the output shaft, in arc-minutes, so the 10:1 to 40:1 reduction range does not reduce it. Three arc-minutes is 8.7 × 10⁻⁴ rad; at a 50 mm sprocket pitch radius that is 44 µm at the carrier — already larger than the whole ±0.03 mm figure a positioned station is supposed to hold. It only appears when the carrier reverses. On a loop that always runs one way, it never enters the budget at all, which is the single strongest argument for indexing a circular conveyor in one direction only and letting it complete the loop rather than shuttling back.
The drive element has its own periodicity.
Chain pitch tolerance and belt tooth pitch error do not repeat with the station spacing; they repeat with the length of the chain or belt loop. Unless the loop length happens to be an exact multiple of the station pitch, a different set of links or teeth carries the load each time the carrier arrives, and the error walks slowly through the budget over many cycles. A repeatability test of twenty consecutive passes can miss this entirely and report a figure the line will not hold across a shift.
Why chain reaches ±0.03 mm where timing belt reaches ±0.05 mm
This is counterintuitive to most people specifying the line. A timing belt is normally the smoother, quieter, more precise-feeling option, and on a linear axis it usually is. On a circular conveyor with a positioning mechanism, chain is the more repeatable of the two.
The reason of this Circular Conveyor Positioning Accuracy is what happens after the stop engages. The positioning mechanism pulls the carrier onto its datum, but the carrier is still coupled to the drive element, and the drive element still has whatever tension and compliance it had when the carrier arrived. That stored elastic energy pushes back.
- A chain engages its sprocket positively, link by link. The links themselves are rigid steel, and the compliance in the loop is dominated by pitch clearance rather than by material stretch. Once the carrier is pulled onto its stop, there is very little stored spring to push it off again.
- A timing belt holds position through tooth flanks that deform elastically under load, over a free span that also stretches in proportion to its length and tension. The longer the straight sections, the more compliance sits between the drive pulley and the carrier. The stop still wins, but it wins against a spring rather than against a rigid member, and the residual is larger.
Two consequences follow from that, and both are useful at the layout stage. The first is that belt-drive repeatability is not uniform around the loop: a station close to the drive pulley has a shorter compliant path than a station on the far side, so the ±0.05 mm figure is an envelope across stations rather than a constant. If one station on a belt-driven line is the critical one, putting it near the drive is free. The second is that belt tension is now an accuracy parameter and not only a slip parameter, because the restoring force the stop has to overcome scales with it.
What sets the stop’s own repeatability
Once the mechanism is doing the work, the error sources change completely. The transmission drops out, and four new ones take its place. Each of them is a commissioning or maintenance variable rather than a purchased specification, which is why two identical lines can hold different figures.
Actuator force variation.
The stop face deflects elastically under the force pressing the carrier onto it, and that deflection is part of the resting position. If the clamping force changes, the resting position changes with it. On a pneumatic mechanism the force follows supply pressure directly, so a regulator that drifts, or a filter that is loading up, shows as positioning scatter rather than as a pressure alarm.
Simultaneous actuation.
A loop with several positioning mechanisms firing on the same index pulse draws from the same manifold at the same instant. If the receiver and line sizing do not support it, pressure dips during the stroke and every station sees a lower force than it saw in single-station testing. This is a common reason a line meets its figure during commissioning, when stations are proved one at a time, and misses it in production.
Approach speed and dwell.
The stop has to arrest the carrier, not merely touch it. Arriving fast leaves residual energy that shows as bounce, and reading the position before it has settled reports a number that the process will not see either. Standard practice on indexing lines is to decelerate into the stop zone well below line speed and to cushion the contact, pneumatically or with a shock absorber, so that the carrier arrives with little energy to give back. The dwell needed before the process equipment engages is a real cycle-time cost and belongs in the cycle calculation rather than being discovered later.
Contact condition.
This is one hard contact, so anything sitting in it is a direct offset: a film of oil, a particle, a burr raised by the first few thousand engagements. Wear on the stop face and on the carrier datum moves the figure in one direction over time, which distinguishes it from the other three — wear shows as drift, not as scatter.
Carrier-to-carrier spread is not the same as carrier repeatability
A published repeatability figure answers the question “how closely does this carrier return to this station?” The question the process equipment is actually asking is “how closely does whichever carrier arrives next present the workpiece?”
Those are the same question only on a single-carrier line. On a loop with eight carriers, the datum feature that the mechanism engages has been machined eight times, and the position of that feature relative to the carrier’s mounting surface carries a manufacturing tolerance that no positioning mechanism can remove. The mechanism repeats to the datum; it does not repeat to the fixture.
This matters most in two situations. One is a line where carriers are not sequenced, so any carrier can arrive at any station. The other is a line where a carrier has been replaced or rebuilt mid-life and the replacement was not matched to the original. In both, the useful figure is the envelope across the carrier set, and the way to establish it is to measure every carrier at one station rather than one carrier at every station.
Where the process genuinely cannot absorb the spread, the standard answer is not tighter carrier machining. It is to reference the process to the carrier — a vision correction, or a fixture that locates off the same datum the mechanism uses — so that carrier-to-carrier variation drops out of the loop entirely.
Stations without a mechanism keep the ±0.5 mm figure
Worth stating plainly because it is assumed away in most enquiries: the mechanism acts at the station where it is fitted, and nowhere else. A twelve-station loop with four positioning mechanisms has four stations at the positioned figure and eight at ±0.5 mm.
Positioning mechanisms for Circular Conveyor Positioning Accuracy are configured per station, so this is a quotation decision rather than a property of the line. The specification should list which stations are positioned, and any station that is going to acquire a precision process later is cheaper to fit now than to retrofit into a built loop.
What the Circular Conveyor Positioning Accuracy figure does not include
The published figure is the repeatability of the carrier at a positioning station, measured on a correctly built and correctly set-up line. Four things sit outside it and will show up as positioning problems that no adjustment of the mechanism will fix:
Slide preload.
A slide with too little roller preload has play, and play appears as positioning scatter that gets worse with fixture mass. This is the first thing to check when a line that met specification at commissioning starts drifting. See Eccentric Roller Adjustment.
Rail joint alignment.
Where two rail sections meet, a step or an angular mismatch changes the carrier’s attitude as it crosses. The tolerance on that joint is 0.03 mm for both step and gap — the same order as the entire positioning budget at a chain-driven station, which is why a positioning station should not be placed over or immediately after a joint if the layout allows any choice. The same applies to the mounting frame beneath it: the frame flatness specification is ±0.15 mm within any 3 m and ±0.3 mm within any 10 m, so a station sitting on a local high or low spot is being positioned against a datum that moved after the line was set. See Circular Rail Joint Accuracy.
Thermal expansion of the loop.
Station positions are set at one temperature and the track grows at another. The arithmetic is not marginal. An aluminium structure expands at roughly 23 µm per metre per °C, so two stations 1,500 mm apart move 0.35 mm relative to each other over a 10 °C swing; a steel structure, at roughly 11–12 µm/m/°C, moves about half that. Either figure dwarfs the ±0.03 mm repeatability the line holds at each station individually. With standard arc diameters now reaching 800 and 1000 mm, the absolute path around a large loop is long enough that this is the governing term for any process referenced to a fixed external frame, and it is the reason a line can hold ±0.03 mm repeatability and still drift out of tolerance against a machine that is not growing with it.
Fixture compliance above the carrier.
The figure describes the carrier, not the workpiece. A tall or cantilevered fixture adds its own deflection under process force, and that deflection is not in any conveyor specification.
It also adds an amplification that is easy to miss. The carrier can rotate slightly as the stop engages, and each rotation has its own lever arm: pitch, about the transverse horizontal axis, is amplified by the height of the tool point above the carrier datum, while yaw, about the vertical axis, is amplified by the tool point’s horizontal offset from the centre of rotation. Pitch is usually the one that bites, because the stop’s line of action rarely sits at the same height as the roller reactions holding the carrier, so engaging it applies a pitching couple. A rotation of one hundredth of a degree — 1.7 × 10⁻⁴ rad, well inside normal roller clearance — becomes 35 µm at a tool point 200 mm above the carrier, and 17 µm at 100 mm. The conveyor is inside its specification and the process is out of tolerance, and the fixes at that point are to lower the tool point, or to locate the fixture off the same datum the mechanism engages.

At the carrier datum the line is inside ±0.03 mm; at a tool point 200 mm up it is 35 µm out.
Repeatability, not absolute accuracy
These are repeat positioning figures: how closely the carrier returns to the same station on successive passes. They are not statements of absolute position against a machine coordinate system, and they should not be quoted as such in a specification that a customer’s inspection department will test against.
Where absolute station-to-station position matters — a robot picking from two stations without vision correction, for example — the planar accuracy of the assembly base becomes the governing figure rather than the carrier repeatability. That figure is ±0.05 mm, and unlike repeatability it does not improve when a positioning mechanism is fitted, because the mechanism can only return the carrier to a datum that the base has already placed.
The practical split is worth keeping in mind when a requirement arrives: repeatability is bought from the mechanism, absolute accuracy is bought from the base and the installation, and thermal stability is bought from the layout and the environment. Three different budgets, three different suppliers of the error, and a requirement that mixes them will be quoted wrongly by whoever reads it fastest.
Verifying Circular Conveyor Positioning Accuracy on site
The published number is only as good as the test that confirms it, and most disputes come from two sides measuring different quantities. The following sequence establishes the figure the catalogue is claiming.
- Reference the indicator to the machine base, not to the conveyor frame. A stand clamped to the conveyor moves with whatever it is trying to measure.
- Contact a flat on the carrier with the probe axis parallel to the direction of travel. At a rod-located station, set up a second indicator on the radial axis and test it against the same figure, because the mechanism is holding that axis too. At a cylinder-stop station, radial and vertical are guideway figures, need their own setups, and are reported separately against guideway tolerances rather than against the positioning specification.
- Cycle the line to thermal steady state first. Readings taken from cold will show drift, and drift is not repeatability.
- Return the carrier over at least a full station pitch between readings, always in the production direction of travel, and let the mechanism complete its stroke and dwell before reading.
- Take enough passes to cover at least one full revolution of the chain or belt, not a fixed count of twenty. This is the only way the drive element’s own periodicity shows up.
- Report the band and the convention together: maximum minus minimum, the ± half of it, and the number of passes. If the customer’s acceptance is written to a machine-tool standard, compute their value from the same data set rather than converting.
- Repeat for every carrier at one station if carriers are not sequenced, and report the envelope.
A clause that reflects what the product actually delivers reads along these lines:
Repeat positioning accuracy at positioned stations shall be within ±0.03 mm (chain drive), as the half-spread of not fewer than N consecutive unidirectional approaches at thermal steady state, with the indicator referenced to the machine base. The clause applies along the direction of travel at all positioned stations, and additionally in the radial direction at stations fitted with a pneumatic rod mechanism. Radial position at cylinder-stop stations, vertical position at all stations, and every station not fitted with a positioning mechanism are excluded from this clause and are specified separately.
When a line stops holding its figure
Positioning faults sort quickly by the shape of the error rather than its size, and the shape points at a different subsystem in each case.
| What you see | Where to look first |
| Scatter that grows with fixture mass | Roller preload — see Eccentric Roller Adjustment |
| One-sided step that appeared suddenly | Contamination or a burr on the stop face or carrier datum |
| Slow drift in one direction over months | Wear on the stop face and datum |
| Drift over a shift, recovering overnight | Thermal growth of the loop, not the mechanism |
| Scatter at some stations only | Proximity to a rail joint, or belt span length at that station |
| Radial scatter at a rod-located station | Rod-to-bush clearance, or roller preload unloading against the rod |
| Radial scatter at a cylinder-stop station | Expected — that axis is set by the guideway, not the mechanism |
| Scatter with a long, slow period | Chain or belt periodicity against station pitch |
| Appeared when the line went to full production rate | Air supply during simultaneous actuation, or insufficient dwell |
The maintenance and troubleshooting hub carries the corrective procedures for each of these.
Related published figures of Circular Conveyor Positioning Accuracy
For context, the parameter set that accompanies these accuracy figures on a typical configured line:
| Parameter | Published range |
| Servo power | 750 – 2000 W |
| Gearbox reduction ratio | 10:1 – 40:1 |
| Planar accuracy | ±0.05 mm |
| Distance between adjacent stations | 110 – 2000 mm |
Link drive (L20)
Repeat positioning accuracy for link drive (L20) lines — called connecting rod drive in older material — is not covered by the three figures above and is confirmed per application rather than published. The reason is structural rather than administrative: a link drive sets carrier position through the geometry of the linkage itself, so its repeatability follows from the link lengths and the crank angle at the station and does not reduce to a single figure for the drive type. The product page for that drive type is on TallMan Robotics at Link Drive Circular Conveyor.
How to Make Circular Conveyor Maintenance and Troubleshooting?
Sources and references about Circular Conveyor Positioning Accuracy
Primary sources are first-party. Every published figure on this page — the three repeat positioning accuracy values, the 0.03 mm joint step and gap tolerance, the mounting frame flatness specification, the planar accuracy and the parameter ranges in the table above — comes from the Circular Conveyor System catalogue (edition 2027.1) and from engineering confirmations recorded during its revision. Where a catalogue value has been superseded, that is stated at the point it appears rather than left for the reader to reconcile.
Measurement conventions. ISO 230-2, Test code for machine tools — Part 2: Determination of accuracy and repeatability of positioning of numerically controlled axes, is the reference behind the distinction drawn above between a half-spread and a statistically derived repeatability value, and behind the separation of unidirectional from bidirectional testing.
Material data. The linear thermal expansion coefficients used in the worked example are standard published values for structural aluminium alloy (approximately 23 µm/m/°C) and for carbon and alloy steels (approximately 11–12 µm/m/°C).
Locating geometry. The two rod constructions described — a conical lead-in with a cylindrical locating land, and a full taper into a matching tapered seat — are long-established fixturing practice rather than anything particular to this product. The hybrid construction, in which a tapered front performs the initial location and a straight section then enters a straight bore to do the final locating, is set out in US Patents 4,058,885 and 4,179,106. Final positioning by taper cones seating into complementary tapered holes in a pallet is described in US Patent Application 2009/0206225. For general selection guidance on locating and fixturing pins, including the use of a conical lead-in for entry and of paired pins to control rotation, see GlobalSpec, “Locating and Fixturing Pins Selection Guide” (globalspec.com), and Metrol, “What Are Locating Pins? Types, Selection Criteria, and Practical Shop-Floor Insights” (metrol-sensor.com).
Stop and locator as separate functions. The practice of arresting a carrier with one device and locating it with another, and of adding a second locating feature where rotation has to be held, is general to pallet-transfer automation and is documented in the pallet lift-and-locate literature cited above and in the same patent material.
Check Quality Control? Request a quote? Check Video Gallery? Conveyor Cycle Time Calculation?